mSORB™ REFRIGERANT DESICCANT
mSORB™ REFRIGERANT DESICCANT

mSORB RG-7™

mSORB RG™ refrigerant desiccants provide excellent water capacity, high physical strength, and high attrition resistance when activated or hydrated allowing for use in high vibration applications such as mobile air conditioning.


 
 
Typical Applications
Typical Applications

mSORB RG™ refrigerant desiccants are specifically formulated to be used as desiccants for stationary and mobile air conditioning and refrigeration systems in the commercial, automotive, and appliance industries.

Chemical Formula
Chemical Formula

Ca4,5 [(Al02)12(SiO2)12] · nH2O

 

REFRIGERATION COMPATABILITY

This information can be used to determine the recommended desiccant for a refrigerant blend. The desiccant of choice will be that which is compatible with all components of the blend.

REFRIGERANT RG-7™ RG-9™ RG-11™
HC-600 Yes Yes Yes
HC-290 Yes Yes Yes
HFC-32 No Yes1 Yes
HFC-125 Yes Yes Yes
FC-134a Yes Yes Yes
HFC-143a Yes Yes Yes
HFC-152a No Yes2 Yes
HFC-404A Yes Yes Yes
HFC-407C No No Yes
HFC-410A No No Yes
HCFC-22 Yes Yes Yes
HCFC-123 Yes Yes Yes
HCFC-124 Yes Yes Yes
HCFC-142b Yes Yes Yes
CFC-11 Yes Yes Yes
CFC-12 Yes Yes Yes

1mSorb RG-9 can be used to dry HFC-32, although it does adsorb HFC-32 concurrently.

2The us of mSorb RG-9 with HFC-152a should be carefully evaluated; however, we believe that there is not a great risk of incompatibility.

SPECIFICATIONS OF mSORB RG™ REFRIGERANT DESICCANT
  RG-7™ RG-9™ RG-11™  
Bead Size 8 x 12 8 x 12 2-3 mm  
Normal Pore Opening 3 3 3 Angstroms
Equilibrium Water Capacity (4.6 Torr @ 25°C) ≥ 17.0 ≥ 16.5 ≥ 16.0 % Weight
Heat of Adsorption 1800 1800 1800 BTU/lb of H2O
Bulk Density ≥ .85 ≥ .85 ≥ .85 g/ml
≥ 53 ≥ 53 ≥ 53 lb/ft3
Crush Strength ≥ 15 ≥ 7 ≥ 15 lb
≥ 65 ≥ 65 ≥ 65 N
Dry Attrition ≤ 0.5 ≤ 0.5 ≤ 0.5 % Weight
Hydrated Attrition ≤ 1.5 ≤ 1.5 ≤ 1.5 % Weight
Size Qualification ≥ 97 ≥ 97 ≥ 97 %
LOI ≤ 1.5 ≤ 1.5 ≤ 1.5 % Weight
PACKAGING INFORMATION FOR mSORB RG™ REFRIGERANT DESICCANT
Drums 180 kg / 396 lb
Super Sacks Fill weight to order specification
Contact Us
Contact Us
 

Interra Global Corp.

800 Busse Hwy.
Park Ridge,IL 60068

847.292.8600

F: 847.292.8601 

IMPORTANT
IMPORTANT

mSORB RG™ molecular sieves are formulated to be compatible with the refrigerants and lubricants that they are intended to operate with and will prevent chemical reactions that could produce system failures. 

STORAGE
STORAGE

Store refrigerant desiccant in a dry location to prevent premature water adsorption. Reseal packages after opening to prevent contamination and unintended water adsorption. We recommend that you rotate stock so oldest material is used first.

Health & Safety
Health & Safety
Health and Safety Information is available on our product MSDS. 